End-to-End Liquid Cooling Project Delivery

  • Solution design
  • Manufacturing
  • Deployment

Integrated engineering, in-house manufacturing, and on-site deployment for liquid cooling infrastructure, from individual cooling components to rack-level systems and liquid-cooled data centers.

Liquid Cooling Adaptability Across L10, L11, and L12

SynthCool adapts liquid cooling solutions to different levels of computing infrastructure, from chip-level cold plate cooling to integrated rack systems and data center-wide cooling infrastructure.

L10

Chip-Level Cooling

Direct-to-chip liquid cooling for processors and other high-heat-load components, with remaining components primarily air-cooled.

L11

Rack-Level Integration

Integrated liquid cooling for rack-scale computing systems, coordinating cooling distribution, piping, and control to meet system requirements.

L12

Liquid-Cooled Data Centers

Data center-level cooling infrastructure integrating cooling sources, distribution systems, terminal cooling, and intelligent control.

Our Core Delivery Capabilities

Integrated Solution Design

From requirements analysis to detailed engineering design.

  • Primary-side cooling source selection
  • AI-driven cooling control and optimization
  • Terminal liquid cooling solution design

Customized engineering: Solutions tailored to compute density, facility conditions, and PUE targets.

Secondary-Side Manufacturing

In-house R&D and manufacturing of core products.

  • CDU design and manufacturing
  • CDU control logic adaptation for project-specific requirements
  • Rapid fabrication of secondary-side piping

Factory quality control: Pressure testing, flushing, and other applicable procedures completed before delivery.

On-Site Deployment

Professional on-site deployment from equipment installation to system commissioning.

  • Primary-side equipment installation
  • CDU deployment
  • Secondary-side piping installation
  • Liquid cooling system commissioning

End-to-end delivery: Full-cycle service from equipment supply to installation and project acceptance.

How We Deliver Liquid Cooling Projects

Requirements Analysis

Assess compute density, site conditions, cooling requirements, and energy-efficiency targets.

Solution Engineering

Define system architecture and configure key components for a tailored cooling solution.

Manufacturing & Testing

Manufacture and prepare core equipment and piping assemblies, with applicable factory tests.

Installation & Commissioning

Install equipment, connect piping, commission the system, and support project acceptance.

Planning a Liquid Cooling Project?

From chip-level cooling to rack integration and data center-wide infrastructure, SynthCool works with you to define a solution that fits your technical and operational requirements.