Two-Phase Immersion Cooling

SynthCool's two-phase immersion cooling delivers efficient, uniform heat dissipation for compact, high-density computing environments.

What Is Immersion Cooling?

Immersion cooling submerges servers in dielectric fluid to remove heat directly from IT components.

How Two-Phase Immersion Cooling Works?

Two-phase immersion cooling removes heat through the phase change of dielectric fluid. Dielectric fluid absorbs heat from server components and boils into vapor. The vapor then condenses, releasing heat and returning to the liquid phase to repeat the cycle.

  1. GPU / CPU

    CPU/GPU generates heat in working.

  2. Two-Phase Tank

    Dielectric fluid absorbs heat from chip surfaces, boils into vapor, and enables continuous liquid replenishment.

  3. Refrigerant Distribution Unit (RDU)

    Drives the phase-change refrigerant and enables condensation and heat exchange.

  4. Phase Control Unit (PCU)

    Controls refrigerant flow and phase conditions.

  5. Facility Cooling

    Connects to the primary cooling source for heat rejection, enabling free cooling and high-density deployment.

Heat transfer diagram showing the supply and return paths through the facility water system, refrigerant distribution unit, and immersion compute tray.

Choosing the Right Liquid Cooling Approach

Direct-to-Chip Cooling

Cold plates capture heat directly from CPUs and GPUs for targeted, high-density cooling.

Best suited for:
  • Large-scale deployments
  • Retrofitting air-cooled data centers
  • Scaling GPU capacity for systems such as NVIDIA GB200
  • High-performance commercial computing and GPU-as-a-Service (GPUaaS)

Immersion Cooling

Dielectric fluid surrounds submerged IT components, removing heat directly from component surfaces.

Best suited for:
  • Small-scale data centers
  • University and research labs
  • Purpose-built facilities requiring uniform cooling across server components

Not sure which cooling approach fits your needs? Talk to our cooling experts to find the right solution for your application.

Immersion Cooling Products

Landau 2PIC Series

The SynthCool Landau 2PIC two-phase immersion cooling solution adopts a low-boiling-point dielectric fluid to fully immerse server electronic components, achieving 100% liquid cooling coverage. The refrigerant directly contacts heat-generating components and absorbs heat through boiling (phase change), ensuring stable, uniform cooling for ultra high-density servers.

Learn more

Ready to Explore Immersion Cooling?

Talk to our experts about your thermal challenges and cooling requirements.